Skip to content

VCRIGHT_a203 — Epbm Over I Static

Full alert identifier: VCRIGHT_a203_epbmOverIStatic

Alert description

Electronic Parking Brake Monitor measured more current than is required for Electronic Parking Brake to remain in PARKING.

Potential impact

Caliper lifetime may be degraded.

Set condition

Electronic Parking Brake attempted to remain in PARKING while Electronic Parking Brake Monitor had measured more than the maximum current allowed to remain in PARKING.

Clear condition

A new Electronic Parking Brake operation starts.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current VCRIGHT_a203_current A
Signal Unit
Desync Count VCRIGHT_a203_desyncCount —
Dyn Apply Allowed VCRIGHT_a203_dynApplyAllowed —
Dynamic Allowed VCRIGHT_a203_dynamicAllowed —
Epb Config VCRIGHT_a203_epbConfig —
Open Allowed VCRIGHT_a203_openAllowed —
Park Allowed VCRIGHT_a203_parkAllowed —
Park Pending Allowed VCRIGHT_a203_parkPendingAllowed —
Parking Allowed VCRIGHT_a203_parkingAllowed —
Show 7 more fields
Signal Unit
Release Allowed VCRIGHT_a203_releaseAllowed —
Service Allowed VCRIGHT_a203_serviceAllowed —
Start Allowed VCRIGHT_a203_startAllowed —
Unknown Allowed VCRIGHT_a203_unknownAllowed —
Wench Pending Allowed VCRIGHT_a203_wenchPendingAllowed —
Winch Allowed VCRIGHT_a203_winchAllowed —
Winch Release Allowed VCRIGHT_a203_winchReleaseAllowed —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a203.

Browse all VCRIGHT alert codes