Skip to content

VCRIGHT_a130 — Blower IC Warning

Full alert identifier: VCRIGHT_a130_blowerICWarning

Alert description

The brushless motor has an integrated circuit warning

Potential impact

The HVAC cabin blower may not be able to run

Set condition

The integrated circuit has detected a condition that should be reported

Clear condition

The CBC integrated circuit no longer detects a fault that requires a stop.

Signals to check

These diagnostic fields are associated with VCRIGHT_a130. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Otw VCRIGHT_a130_OTW —
Pvdd ovfl VCRIGHT_a130_PVDD_OVFL —
Pvdd uvfl VCRIGHT_a130_PVDD_UVFL —
Temp flag1 VCRIGHT_a130_TEMP_FLAG1 —
Temp flag2 VCRIGHT_a130_TEMP_FLAG2 —
Temp flag3 VCRIGHT_a130_TEMP_FLAG3 —
Temp flag4 VCRIGHT_a130_TEMP_FLAG4 —
Vcph uvfl VCRIGHT_a130_VCPH_UVFL —
Show 6 more fields
Signal Unit
Vds status VCRIGHT_a130_VDS_STATUS —
Junction Over Temp VCRIGHT_a130_junctionOverTemp —
Junction Temp Warning VCRIGHT_a130_junctionTempWarning —
Loss Of Speed Lock VCRIGHT_a130_lossOfSpeedLock —
Start Up Operation VCRIGHT_a130_startUpOperation —
Vcc Under Voltage VCRIGHT_a130_vccUnderVoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a130.

Browse all VCRIGHT alert codes