VCLEFT_a350 — Ens Out Of Range
Full alert identifier: VCLEFT_a350_ensOutOfRange
Alert description
The Emergency Notification Signal (ENS) harness may be disconnected or the Restraints Control Module (RCM) may be missing (MIA).
Potential impact
Loss of redundancy on high voltage disconnection signal.
Set condition
Emergency Notification Signal (ENS) period is not within 10% of 0.001 or 0.1 seconds, and duty cycle is not between 60% and 40%.
Clear condition
ENS period is within 10% of 0.001 or 0.1 seconds and duty cycle is between 60% and 40%.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Ens Duty
VCLEFT_
|
% |
Ens Period
VCLEFT_
|
s |
| Signal | Unit |
|---|---|
Ens Timed Out
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a350.