VCLEFT_a132 — Blower Soft Stall

Full alert identifier: VCLEFT_a132_blowerSoftStall

Alert description

There is a soft stall condition on the brushless motor

Potential impact

The HVAC cabin blower will not be able to run. A reset will take effect to attempt to clear the fault.

Set condition

A non-zero brushless motor RPM is not reaching the target RPM for some time.

Clear condition

The motor RPM reaches its target.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
RPM Actual VCLEFT_a132_RPMActual RPM
RPM Target VCLEFT_a132_RPMTarget RPM

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a132.