VCLEFT_a129 — Blower IC Latch Fault

Full alert identifier: VCLEFT_a129_blowerICLatchFault

Alert description

The brushless motor has an integrated circuit (LV8907 or DRV8305) latched fault

Potential impact

The HVAC cabin blower will not be able to run. The integrated circuit will be reset to attempt to clear the fault

Set condition

The integrated circuit has detected a condition that requires a stop

Clear condition

The LV8907 integrated circuit no longer detects a fault that requires a stop.

Signals to check

These diagnostic fields are associated with VCLEFT_a129. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Avdd uvlo VCLEFT_a129_AVDD_UVLO —
Otsd VCLEFT_a129_OTSD —
Pvdd uvlo2 VCLEFT_a129_PVDD_UVLO2 —
Sns a ocp VCLEFT_a129_SNS_A_OCP —
Sns b ocp VCLEFT_a129_SNS_B_OCP —
Sns c ocp VCLEFT_a129_SNS_C_OCP —
Vcph ovlo abs VCLEFT_a129_VCPH_OVLO_ABS —
Vcph uvlo VCLEFT_a129_VCPH_UVLO —
Show 19 more fields
Signal Unit
Vcph uvlo2 VCLEFT_a129_VCPH_UVLO2 —
Vcp lsd uvlo2 VCLEFT_a129_VCP_LSD_UVLO2 —
Vds ha VCLEFT_a129_VDS_HA —
Vds hb VCLEFT_a129_VDS_HB —
Vds hc VCLEFT_a129_VDS_HC —
Vds la VCLEFT_a129_VDS_LA —
Vds lb VCLEFT_a129_VDS_LB —
Vds lc VCLEFT_a129_VDS_LC —
Vgs ha VCLEFT_a129_VGS_HA —
Vgs hb VCLEFT_a129_VGS_HB —
Vgs hc VCLEFT_a129_VGS_HC —
Vgs la VCLEFT_a129_VGS_LA —
Vgs lb VCLEFT_a129_VGS_LB —
Vgs lc VCLEFT_a129_VGS_LC —
Vreg uv VCLEFT_a129_VREG_UV —
Wd fault VCLEFT_a129_WD_FAULT —
Fet Short Circuit VCLEFT_a129_fetShortCircuit —
Locked Rotor VCLEFT_a129_lockedRotor —
Over Current Error VCLEFT_a129_overCurrentError —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a129.

Browse all VCLEFT alert codes