Skip to content

VCFRONT_a574 — Front Drive Inverter eFuse Trip

Full alert identifier: VCFRONT_a574_frontDriveInverterEFuseTrip

Alert description

The front vehicle controller (VCFRONT) detects an eFuse overcurrent event (or a trip) on the front drive inverter (DIF) power feed.

Potential impact

The DIF may be unavailable, which may limit powertrain performance.

Set condition

The VCFRONT detects an eFuse overcurrent event on the DIF power feed.

Clear condition

The VCFRONT no longer detects an eFuse overcurrent event on the DIF power feed.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Front Drive Inverter Current VCFRONT_a574_frontDriveInverterCurrent A
Front Drive Inverter Voltage VCFRONT_a574_frontDriveInverterVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a574.

Browse all VCFRONT alert codes