Skip to content

VCFRONT_a487 — Front OPC eFuse Fault

Full alert identifier: VCFRONT_a487_frontOPCEFuseFault

Alert description

The front vehicle controller (VCFRONT) detects the front Oil Pump Controller (OPC) eFuse circuit has tripped (circuit opened), interrupting power supply to the front OPC. Powertrain performance may be limited.

Potential impact

Powertrain performance may be limited.

Set condition

The VCFRONT detects the eFuse circuit gating low voltage (LV) power feed to the front OPC as open (tripped).

Clear condition

The VCFRONT no longer detects the eFuse circuit gating low voltage (LV) power feed to the front OPC as open (tripped) after a retry or sleep cycle, or the vehicle enters a state where the eFuse is expected to be open (off).

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Front OPCE Fuse Current VCFRONT_a487_frontOPCEFuseCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a487.

Browse all VCFRONT alert codes