Skip to content

VCFRONT_a483 — Lv Bridge Voltage Mismatch

Full alert identifier: VCFRONT_a483_lvBridgeVoltageMismatch

Alert description

The vehicle controller detects there is voltage mismatch greater than 0.5V between the input power to the front vehicle controller (VCFRONT) and low voltage (LV) bridge circuit.

Potential impact

Vehicle functions that depend on the LV bridge may be unavailable, or their performance may be affected.

Set condition

The voltage mismatch is greater than 0.5V between the VCFRONT printed circuit board assembly (PCBA) input voltage and the eFuse output voltage.

Clear condition

The voltage mismatch is less than 0.5V between the VCFRONT printed circuit board assembly (PCBA) input voltage and the eFuse output voltage.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
E Fuse Voltage VCFRONT_a483_eFuseVoltage V
Vbat Prot Voltage VCFRONT_a483_vbatProtVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a483.

Browse all VCFRONT alert codes