Skip to content

VCFRONT_a473 — Three Way Valve Fault

Full alert identifier: VCFRONT_a473_threeWayValveFault

Alert description

The front vehicle controller (VCFRONT) detects the three-way valve has encountered a condition preventing it from performing as designed.

Potential impact

Vehicle functions that rely on the three-way valve may be limited or unavailable.

Set condition

The three-way valve encounters a condition preventing it from performing as designed. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

Clears after 5 seconds.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current VCFRONT_a473_current mA
Feed Back Voltage VCFRONT_a473_feedBackVoltage V
Position VCFRONT_a473_position %
Signal Unit
Feedback Voltage Implausible High VCFRONT_a473_feedbackVoltageImplausibleHigh —
Feedback Voltage Implausible Low VCFRONT_a473_feedbackVoltageImplausibleLow —
Over Current VCFRONT_a473_overCurrent —
Timeout Reaching Target VCFRONT_a473_timeoutReachingTarget —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a473.

Browse all VCFRONT alert codes