Skip to content

VCFRONT_a409 — Invalid Configuration

Full alert identifier: VCFRONT_a409_invalidConfiguration

Alert description

The front vehicle controller (VCFRONT) detects an invalid coolant pump configuration. Powertrain thermal management and performance may be limited. A VCFRONT reset will typically clear the alert by correctly configuring the pump.

Potential impact

The coolant pump may not work as expected, limiting powertrain thermal management and performance.

Set condition

The coolant pump configuration detected does not match the configuration expected by VCFRONT.

Clear condition

The coolant pump configuration detected matches the configuration expected by VCFRONT, which may occur after a VCFRONT reset.

Signals to check

These diagnostic fields are associated with VCFRONT_a409. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Brushless Motor Configuration Invalid VCFRONT_a409_brushlessMotorConfigurationInvalid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a409.

Browse all VCFRONT alert codes