VCFRONT_a355 — Coolant Sys Lockout

Full alert identifier: VCFRONT_a355_coolantSysLockout

Alert description

The vehicle controller detects the vehicle is not factory gated or the coolant is not filled, causing the coolant pumps to turn off and the coolant valve to be in Series or No Bypass mode.

Potential impact

Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.

Set condition

May set due to any of the following: (1) vehicle is not factory gated; (2) coolant is not filled; (3) coolant fill / drain routine is active.

Clear condition

May clear due to any of the following: (1) vehicle is factory gated; (2) coolant is filled; (3) coolant fill / drain routine is complete.

Signals to check

These diagnostic fields are associated with VCFRONT_a355. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Factory Gated VCFRONT_a355_factoryGated —
Fluid Not Filled VCFRONT_a355_fluidNotFilled —
Service Lockout VCFRONT_a355_serviceLockout —
System Not Commissioned VCFRONT_a355_systemNotCommissioned —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a355.

Browse all VCFRONT alert codes