VCFRONT_a344 — Pcs Fast Trip Slope
Full alert identifier: VCFRONT_a344_pcsFastTripSlope
Alert description
The front vehicle controller (VCFRONT) detects the electrical current flowing through the power conversion system (PCS) eFuse has equaled or exceeded a current slope value (rate of change) of 120A per millisecond.
Potential impact
The eFuse circuit may open (trip), interrupting low voltage power supply to the PCS. This could make PCS functions limited or unavailable, and could interrupt precharging of the high voltage (HV) bus .
Set condition
The PCS eFuse current slope value equals or exceeds 120A per millisecond.
Clear condition
The PCS eFuse current slope value is below 120A per millisecond.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Avg Current
VCFRONT_
|
A |
Max Current
VCFRONT_
|
A |
Max Slope
VCFRONT_
|
A/ms |
| Signal | Unit |
|---|---|
Vehicle State
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a344.