Skip to content

VCFRONT_a335 — Vcright Fast Trip OC Max

Full alert identifier: VCFRONT_a335_vcrightFastTripOCMax

Alert description

The front vehicle controller (VCFRONT) detects the electrical current flowing through the right vehicle controller (VCRIGHT) eFuse has equaled or exceeded 100A during the previous 10 milliseconds.

Potential impact

The eFuse circuit may open (trip), interrupting power supply to VCRIGHT and making VCRIGHT unavailable.

Set condition

The VCRIGHT eFuse current value equals or exceeds 100A during the previous 10 milliseconds.

Clear condition

The VCRIGHT eFuse current value remains below 100A during the subsequent 10 milliseconds.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Avg Current VCFRONT_a335_avgCurrent A
Max Current VCFRONT_a335_maxCurrent A
Max Slope VCFRONT_a335_maxSlope A/ms
Signal Unit
Vehicle State VCFRONT_a335_vehicleState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a335.

Browse all VCFRONT alert codes