Skip to content

VCFRONT_a285 — Evaporator Exv Fault

Full alert identifier: VCFRONT_a285_evaporatorExvFault

Alert description

The vehicle controller detects the evaporator electronic expansion valve (EXV) motor driver is reporting an electrical condition (short or disconnect).

Potential impact

Cabin climate control system air conditioning and heating may be limited or unavailable. Powertrain performance may be limited.

Set condition

The evaporator EXV motor driver is reporting an electrical condition (short or disconnect).

Clear condition

The evaporator EXV motor driver no longer reports an electrical condition (short or disconnect).

Signals to check

These diagnostic fields are associated with VCFRONT_a285. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Charge Pump Undervoltage VCFRONT_a285_chargePumpUndervoltage —
Driver Has Comm Error VCFRONT_a285_driverHasCommError —
Driver State VCFRONT_a285_driverState —
Driver Therm Shutdown VCFRONT_a285_driverThermShutdown —
Driver Therm Warn VCFRONT_a285_driverThermWarn —
Is Coil Open X VCFRONT_a285_isCoilOpenX —
Is Coil Open Y VCFRONT_a285_isCoilOpenY —
Is Coil Short XN Gnd VCFRONT_a285_isCoilShortXNGnd —
Show 8 more fields
Signal Unit
Is Coil Short XN Vbb VCFRONT_a285_isCoilShortXNVbb —
Is Coil Short XP Gnd VCFRONT_a285_isCoilShortXPGnd —
Is Coil Short XP Vbb VCFRONT_a285_isCoilShortXPVbb —
Is Coil Short YN Gnd VCFRONT_a285_isCoilShortYNGnd —
Is Coil Short YN Vbb VCFRONT_a285_isCoilShortYNVbb —
Is Coil Short YP Gnd VCFRONT_a285_isCoilShortYPGnd —
Is Coil Short YP Vbb VCFRONT_a285_isCoilShortYPVbb —
Undervoltage VCFRONT_a285_undervoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a285.

Browse all VCFRONT alert codes