Skip to content

VCFRONT_a168 — Hcm Short To VBAT

Full alert identifier: VCFRONT_a168_hcmShortToVBAT

Alert description

The headlamp control module has detected an electrical problem.

Potential impact

One or both headlamps may not function.

Set condition

A short to VBAT is detected in the left or right headlamp module.

Clear condition

A short to VBAT is no longer detected.

Signals to check

These diagnostic fields are associated with VCFRONT_a168. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Left ECU VCFRONT_a168_leftECU —
Right ECU VCFRONT_a168_rightECU —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a168.

Browse all VCFRONT alert codes