Skip to content

VCFRONT_a160 — Compressor Inhibited

Full alert identifier: VCFRONT_a160_compressorInhibited

Alert description

The vehicle controller detects a condition affecting the refrigerant compressor, which may prevent the refrigerant compressor from running as expected. This alert is set in addition to one or more alert(s) indicating a specific condition affecting refrigerant compressor functionality.

Potential impact

Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.

Set condition

At least one additional alert is present indicating a condition affecting refrigerant compressor functionality. Alert log signal data should provide more information on the specific condition(s) detected.

Clear condition

Additional alert(s) indicating a condition affecting refrigerant compressor functionality clear.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Compressor Rpm VCFRONT_a160_compressorRpm RPM
Signal Unit
Fault Sns Ambient Temp VCFRONT_a160_faultSnsAmbientTemp —
Fault Sns Disch Press VCFRONT_a160_faultSnsDischPress —
Fault Sns Disch Temp VCFRONT_a160_faultSnsDischTemp —
Fault Sns Suct Press VCFRONT_a160_faultSnsSuctPress —
Fault Sns Suct Temp VCFRONT_a160_faultSnsSuctTemp —
Fault Valve EXV VCFRONT_a160_faultValveEXV —
Fault Valve Evap Sol VCFRONT_a160_faultValveEvapSol —
High Disch Pressure VCFRONT_a160_highDischPressure —
Show 5 more fields
Signal Unit
High Disch Temp VCFRONT_a160_highDischTemp —
High Discharge Pressure Cutouts VCFRONT_a160_highDischargePressureCutouts —
High Discharge Temp Cutouts VCFRONT_a160_highDischargeTempCutouts —
Low Disch Pressure VCFRONT_a160_lowDischPressure —
Low Suction Pressure VCFRONT_a160_lowSuctionPressure —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a160.