VCFRONT_a129 — Pcs eFuse Trip
Full alert identifier: VCFRONT_a129_pcsEFuseTrip
Alert description
The front vehicle controller (VCFRONT) has opened the low voltage (LV) power feed circuit (eFuse) to the power conversion system (PCS), interrupting power supply to the PCS..
Potential impact
The vehicle low voltage electrical system will no longer be supported by the PCS. Features may be limited or unavailable. The vehicle may use loadshedding (switching off nonessential features) to preserve power for essential functions, with at least one other alert present to indicate this condition.
Set condition
VCFRONT detects the eFuse circuit gating low voltage (LV) power feed to the PCS as open (tripped).
Clear condition
VCFRONT no longer detects the eFuse circuit gating low voltage (LV) power feed to the PCS as open (tripped) after a retry or sleep cycle, or the vehicle enters a state where the eFuse is expected to be open (off).
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pcs E Fuse Current
VCFRONT_
|
A |
Pcs E Fuse Temp
VCFRONT_
|
degC |
Pcs E Fuse Voltage
VCFRONT_
|
V |
| Signal | Unit |
|---|---|
Pcs E Fuse Remaining Retries
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a129.