Skip to content

VCBATT_a540 — Left Fog Light Guide Light Fault

Full alert identifier: VCBATT_a540_leftFogLightGuideLightFault

Alert description

An electrical error has been detected with the left fog light guide (white light pipe in front fascia that turns on along with fog light).

Potential impact

The left fog light guide may not be working.

Set condition

The high side driver (HSD) for the left fog light guide reports that an undercurrent or short circuit condition is present.

Clear condition

The undercurrent or short circuit condition is no longer present.

Signals to check

These diagnostic fields are associated with VCBATT_a540. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Current Sense Faulted VCBATT_a540_currentSenseFaulted —
Output Faulted VCBATT_a540_outputFaulted —
Over Current VCBATT_a540_overCurrent —
Over Temperature VCBATT_a540_overTemperature —
Temp Sense Faulted VCBATT_a540_tempSenseFaulted —
Under Current VCBATT_a540_underCurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a540.