VCBATT_a508 — Bridge eFuse Load Shed

Full alert identifier: VCBATT_a508_bridgeEFuseLoadShed

Alert description

The Bridge EFuse current reached 120A and is at danger of tripping the EFuse if LV loads are not decreased

Potential impact

Convenience features will be disabled to limit LV system current draw

Set condition

The Bridge EFuse is greater than 120A for 100ms

Clear condition

The Bridge EFuse current is less than 120A until Bridge EFuse Loadshed Stage is MIN

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp VCBATT_a508_ambientTemp degC
Bridge E Fuse Current VCBATT_a508_bridgeEFuseCurrent A
Bridge E Fuse Temp VCBATT_a508_bridgeEFuseTemp degC
Signal Unit
Frunk Open VCBATT_a508_frunkOpen —
Service Mode VCBATT_a508_serviceMode —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a508.

Browse all VCBATT alert codes