VCBATT_a508 — Bridge eFuse Load Shed
Full alert identifier: VCBATT_a508_bridgeEFuseLoadShed
Alert description
The Bridge EFuse current reached 120A and is at danger of tripping the EFuse if LV loads are not decreased
Potential impact
Convenience features will be disabled to limit LV system current draw
Set condition
The Bridge EFuse is greater than 120A for 100ms
Clear condition
The Bridge EFuse current is less than 120A until Bridge EFuse Loadshed Stage is MIN
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Ambient Temp
VCBATT_
|
degC |
Bridge E Fuse Current
VCBATT_
|
A |
Bridge E Fuse Temp
VCBATT_
|
degC |
| Signal | Unit |
|---|---|
Frunk Open
VCBATT_
|
— |
Service Mode
VCBATT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a508.