Skip to content

VCBATT_a496 — LV Battery Exit Drive Warning

Full alert identifier: VCBATT_a496_LVBatteryExitDriveWarning

Message shown in the car

Vehicle is preparing to shut down PULL OVER SAFELY

Alert description

The low voltage (LV) battery is in a critical state and the vehicle controller is about to trigger a graceful exit from drive (also known as a graceful power-off, or GPO). At least one other alert should be present when the vehicle starts to exit drive / graceful power-off occurs.

Potential impact

The vehicle will exit drive within the next few minutes, with a separate alert present to indicate that condition, and the next drive cycle will be blocked.

Set condition

May set due to a condition or combination of conditions indicating the LV battery cannot support the vehicle, including: the LV battery internal protection transistor (MOSFET) is open, the reverse battery eFuse has tripped (is open), or the vehicle controller is actively shedding vehicle electrical loads to conserve energy for essential functions. Alert log signal data should provide more information.

Clear condition

No condition or combination of conditions is detected indicating the LV battery cannot support the vehicle, or the vehicle has already entered graceful power-off (GPO) and is actively exiting drive.

Signals to check

These diagnostic fields are associated with VCBATT_a496. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
MOS State VCBATT_a496_MOSState
0
OPEN
1
CLOSED
2
INVALID
3
SNA
—
Not Enough Power For Support VCBATT_a496_NotEnoughPowerForSupport —
Pcs mia VCBATT_a496_PCS_MIA —
Bms State VCBATT_a496_bmsState —
Frunk Open VCBATT_a496_frunkOpen —
Reverse Battery E Fuse Fault VCBATT_a496_reverseBatteryEFuseFault —
Service Mode VCBATT_a496_serviceMode —
Vehicle Load Shed Active VCBATT_a496_vehicleLoadShedActive —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a496.

Browse all VCBATT alert codes