VCBATT_a407 — Dcr Milli Ohms Above Threshold
Full alert identifier: VCBATT_a407_dcrMilliOhmsAboveThreshold
Alert description
The low voltage (LV) battery internal resistance is too high, based on a direct current internal resistance (DCR) calculation. Indicates LV battery replacement is necessary.
Potential impact
The LV battery may be unable to support precharge loads / precharge the high voltage (HV) bus, and requires replacement.
Set condition
Direct current internal resistance (DCR) calculation indicates the LV battery internal resistance exceeds expected threshold (normal operating range).
Clear condition
The vehicle controller loses all electrical power from the LV battery and power conversion system (PCS), as would happen during LV battery replacement.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
IBS Temperature
VCBATT_
|
degC |
Avg Interval Current
VCBATT_
|
A |
Avg Pulse Current
VCBATT_
|
A |
Dcr Milli Ohms
VCBATT_
|
mOhms |
Interval Current Variance
VCBATT_
|
A |
Pulse Current Variance Shifted
VCBATT_
|
A |
Test Counter
VCBATT_
|
— |
| Signal | Unit |
|---|---|
Dcr 12 V Threshold
VCBATT_
|
— |
Opportunistic Test
VCBATT_
|
— |
Testing Expended
VCBATT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a407.