Skip to content

VCBATT_a392 — Air Comp Output Stuck On

Full alert identifier: VCBATT_a392_airCompOutputStuckOn

Alert description

The vehicle controller detects output voltage from the air compressor for the air suspension system when none is expected. The vehicle controller's fused high current eFuse circuit will be used to deenergize the air compressor.

Potential impact

The air compressor for the air suspension system is unavailable, making air suspension functionality limited or unavailable.

Set condition

Air compressor output voltage is detected when the air compressor has been requested off.

Clear condition

Clears automatically on vehicle power state cycle.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Current VCBATT_a392_current A
Time Off VCBATT_a392_timeOff milliseconds
Voltage VCBATT_a392_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a392.

Browse all VCBATT alert codes