Skip to content

VCBATT_a371 — Failure To Precharge Risk

Full alert identifier: VCBATT_a371_failureToPrechargeRisk

Alert description

Based on historical data, the vehicle controller determines there is a high probability the low voltage (LV) battery will not successfully precharge the high voltage (HV) bus.

Potential impact

The high voltage electrical system will remain on to support vehicle functions including drive (HV contactors will remain closed), causing the vehicle show greater range loss over time than expected.

Set condition

Any of the following alerts: 4 instances of LVVoltageDropOnHighLoadCurrent; one instance of shortedCell; one instance of deadLVMinimalAhDischarged; one instance of resistanceEstimationHardFailure; one instance of dcrMilliOhmsAboveThreshold; one instance of prechargeLVLoadReduction.

Clear condition

LV battery replacement should clear this alert.

Signals to check

These diagnostic fields are associated with VCBATT_a371. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Dcr Milli Ohms Above Threshold Trigger VCBATT_a371_dcrMilliOhmsAboveThresholdTrigger —
Dead LV Minimal Ah Discharged Trigger VCBATT_a371_deadLVMinimalAhDischargedTrigger —
Instant Precharge DCR Too High Trigger VCBATT_a371_instantPrechargeDCRTooHighTrigger —
Precharge LV Load Reduction Trigger VCBATT_a371_prechargeLVLoadReductionTrigger —
Resistance Estimation Hard Fail Trigger VCBATT_a371_resistanceEstimationHardFailTrigger —
Shorted Cell Test Trigger VCBATT_a371_shortedCellTestTrigger —
Volt Drop On High Current Trigger VCBATT_a371_voltDropOnHighCurrentTrigger —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a371.

Browse all VCBATT alert codes