VCBATT_a261 — Vcleft Voltage Mismatch

Full alert identifier: VCBATT_a261_vcleftVoltageMismatch

Alert description

There is a greater than 0.5V drop between input power to the vehicle battery controller (VCBATT) and the left vehicle controller circuit.

Potential impact

Potential hardware issue could cause eFuse to trip or VOR.

Set condition

0.5V difference between input voltage to the board and the eFuse.

Clear condition

Less than 0.5V difference between input voltage to the board and the eFuse

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
E Fuse Voltage VCBATT_a261_eFuseVoltage V
Vbat Prot Voltage VCBATT_a261_vbatProtVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a261.

Browse all VCBATT alert codes