Skip to content

VCBATT_a255 — Pump Rad Stopped

Full alert identifier: VCBATT_a255_pumpRadStopped

Alert description

The motor has a fault causing the motor to stop. Powertrain performance may be limited.

Potential impact

Powertrain performance may be limited.

Set condition

The coolant pump's RPM feedback is less than 800 RPM, given a non-zero flow request, either intermittently or continually, for at least 10.5 seconds AND GTW_coolantPumpConfig is not SINGLE_PUMP_BATT.

Clear condition

The feedback RPM is constantly greater than 800 RPM for at least 5.5 seconds.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
RPM Actual VCBATT_a255_RPMActual RPM
RPM Target VCBATT_a255_RPMTarget RPM

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT_a255.