Skip to content

USM_a233 — S7 Init Error

Full alert identifier: USM_a233_s7InitError

Alert description

Alert indicating that there has been an init issue related to the sensor

Potential impact

Sensor function will be impaired, park assist features will be disabled.

Set condition

When any error bit is set by the sensor

Clear condition

When the error condition is no longer present

Signals to check

These diagnostic fields are associated with USM_a233. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Atg Noise Meas Out Of Range USM_a233_atgNoiseMeasOutOfRange —
Cap Loss Vdda Out Of Range USM_a233_capLossVddaOutOfRange —
Cap Loss Vddd Out Of Range USM_a233_capLossVdddOutOfRange —
Crc Mismatch In Eeprom USM_a233_crcMismatchInEeprom —
Crc Mismatch In Otp USM_a233_crcMismatchInOtp —
Crc Mismatch In Ram USM_a233_crcMismatchInRam —
Crc Mismatch In Sysrom USM_a233_crcMismatchInSysrom —
Crc Of Received Cmd Invalid USM_a233_crcOfReceivedCmdInvalid —
Show 26 more fields
Signal Unit
Drv 1 Fail During Burst USM_a233_drv1FailDuringBurst —
Drv 2 Fail During Burst USM_a233_drv2FailDuringBurst —
Drvs Fail During Burst USM_a233_drvsFailDuringBurst —
Eeprom Prog Buys USM_a233_eepromProgBuys —
Eeprom Prog Fail USM_a233_eepromProgFail —
Invalid Start Edge USM_a233_invalidStartEdge —
Num Atg Noise Errors Since Init USM_a233_numAtgNoiseErrorsSinceInit —
Num Invalid Start Edge Since Init USM_a233_numInvalidStartEdgeSinceInit —
Otp Crc Error USM_a233_otpCrcError —
Over Volt At Vtank During Burst USM_a233_overVoltAtVtankDuringBurst —
Password Wrong USM_a233_passwordWrong —
Pdcm Pulse Invalid USM_a233_pdcmPulseInvalid —
Receiver Reached Error State USM_a233_receiverReachedErrorState —
Reference Volt Out Of Range USM_a233_referenceVoltOutOfRange —
Reset USM_a233_reset —
Sram Parity Err USM_a233_sramParityErr —
Sync Count Error USM_a233_syncCountError —
Temp Sens Out Of Range USM_a233_tempSensOutOfRange —
Time Int Between 2 Pulses Err USM_a233_timeIntBetween2PulsesErr —
Trim Reg Parity Err USM_a233_trimRegParityErr —
Under Volt At Vtank During Burst USM_a233_underVoltAtVtankDuringBurst —
Vddd Volt Out Of Range USM_a233_vdddVoltOutOfRange —
Verification Of Config And Calc Params Fail USM_a233_verificationOfConfigAndCalcParamsFail —
Vref Vold Of Otp Out Of Range USM_a233_vrefVoldOfOtpOutOfRange —
Vsup Volt Out Of Range USM_a233_vsupVoltOutOfRange —
Wdg Clock Freq Out Of Range USM_a233_wdgClockFreqOutOfRange —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of USM_a233.

Browse all USM alert codes