Skip to content

UI_a073 — eCall Digital Mic Failed

Full alert identifier: UI_a073_ECallDigitalMicFailed

Alert description

The Ecall audio configurator 'Ecall Digital microphone' test failed

Potential impact

Ecall voice issues or Ecall unavailable

Set condition

Ecall digital microphone RMS amplitude is lower then EcallDigitalMicRMSThreshold (0.02)

Clear condition

Ecall digital microphone test has to pass

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UI_a073.