Skip to content

TAS_a136 — Open Circuit Compressor

Full alert identifier: TAS_a136_openCircuitCompressor

Alert description

Air compressor or air compressor relay detected open circuit.

Potential impact

Air suspension leveling disabled.

Set condition

Air compressor or air compressor relay commanded on but no electrical current measured.

Clear condition

Vehicle-power-state cycle from off to on.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Valve Current TAS_a136_valveCurrent A
Valve Voltage TAS_a136_valveVoltage V
Signal Unit
Valve Fault Type TAS_a136_valveFaultType —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a136.

Browse all TAS alert codes