TAS_a083 — Short Circuit5 V Analog
Full alert identifier: TAS_a083_shortCircuit5VAnalog
Alert description
Off board 5V pressure sensor switched supply is measured to be approximately 0V.
Potential impact
Air suspension leveling will be disabled.
Set condition
Off board 5V pressure sensor switched supply is measured to be approximately 0V.
Clear condition
Vehicle-power-state cycle from off to on.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Voltage 5 V Analog
TAS_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TAS_a083.