Skip to content

RADC_a051 — Mismatch EPAS Type

Full alert identifier: RADC_a051_mismatchEPASType

Alert description

Received EPAS Type Does Not Match Learned Parameter

Potential impact

Sensor is disabled due to not having proper vehicle configuration, radar functions will not be available

Set condition

When the learned parameters meet the ones being sent to the radar on CAN.

Clear condition

As soon as the PROC_RADX_X-PLANT-MODE routine is successfully run.

Signals to check

These diagnostic fields are associated with RADC_a051. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Epas Type Exp RADC_a051_epasTypeExp
0
BOSCH L538
1
BOSCH L405
2
MANDO FGR64
3
MANDO VGR66
4
MANDO VGR63 GEN3
7
SNA
—
Epas Type Rx RADC_a051_epasTypeRx
0
BOSCH L538
1
BOSCH L405
2
MANDO FGR64
3
MANDO VGR66
4
MANDO VGR63 GEN3
7
SNA
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of RADC_a051.

Browse all RADC alert codes