Skip to content

PM_a011 — System Hvil Not Closed

Full alert identifier: PM_a011_systemHvilNotClosed

Alert description

Pedal Monitor Warning: System HVIL not CLOSED

Potential impact

Contactors may not close

Set condition

Any PM unit HVIL status missing or not CLOSED

Clear condition

All PM units report HVIL CLOSED

Signals to check

These diagnostic fields are associated with PM_a011. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Hvil System Status PM_a011_hvilSystemStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—
Pmf Hvil Status PM_a011_pmfHvilStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—
Pmf Status Valid PM_a011_pmfStatusValid —
Pmr Hvil Status PM_a011_pmrHvilStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—
Pmr Status Valid PM_a011_pmrStatusValid —
Pmrel Hvil Status PM_a011_pmrelHvilStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—
Pmrel Status Valid PM_a011_pmrelStatusValid —
Pmrer Hvil Status PM_a011_pmrerHvilStatus
0
DISABLED
1
OPEN
2
CLOSED
3
SNA
—
Show 2 more fields
Signal Unit
Pmrer Status Valid PM_a011_pmrerStatusValid —
Vehicle Power State PM_a011_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a011.

Browse all PM alert codes