PMR_a006 — Under Torque Check
Full alert identifier: PMR_a006_underTorqueCheck
Alert description
Pedal Monitor Warning: DI torque actual does not match PM torque measured
Potential impact
No immediate impact.
Set condition
Set when absolute difference between DIx_torqueActual and PMx_torqueMeasured is > 100Nm for 100ms
Clear condition
This alert will clear 1s after torque difference is below threshold
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Motor RPM
PMR_
|
RPM |
Torque Actual
PMR_
|
Nm |
Torque Measured
PMR_
|
Nm |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMR_a006.