Skip to content

PMRER_a055 — Resolver

Full alert identifier: PMRER_a055_resolver

Alert description

Pedal Monitor Warning: Resolver operation abnormal.

Potential impact

The safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition when resolver speed or angle measurements in correspondence with DI are considered irrational or out of bounds.

Clear condition

This alert will clear on the next drive cycle.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Common Gain PMRER_a055_commonGain 1
Motor RPM PMRER_a055_motorRPM RPM
Phase Angle PMRER_a055_phaseAngle 1
Signal Unit
Cla MIA PMRER_a055_claMIA —
Di Elec Angle Mismatch PMRER_a055_diElecAngleMismatch —
Di Elec Angle Mismatch Warn PMRER_a055_diElecAngleMismatchWarn —
Di MIA PMRER_a055_diMIA —
Di Speed Mismatch PMRER_a055_diSpeedMismatch —
No Carrier PMRER_a055_noCarrier —
Not Ready PMRER_a055_notReady —
Phase Out Of Spec PMRER_a055_phaseOutOfSpec —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a055.

Browse all PMRER alert codes