Skip to content

PMRER_a011 — Phase Current Irrational

Full alert identifier: PMRER_a011_phaseCurrentIrrational

Alert description

Pedal Monitor Warning: Phase Current Irrational.

Potential impact

The safety monitor will initiate a unit limp condition for the remainder of the drive cycle.

Set condition

The safety monitor sets this condition when phase current sensor measurements are irrational or out of bounds.

Clear condition

This alert will clear when phase current sensor measurements are considered rational.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ia PMRER_a011_Ia A
Ia Delta PMRER_a011_IaDelta A
Ib PMRER_a011_Ib A
Ib Delta PMRER_a011_IbDelta A
Current Vref PMRER_a011_currentVref V
Signal Unit
Bad Phase Asample PMRER_a011_badPhaseAsample —
Bad Phase Bsample PMRER_a011_badPhaseBsample —
Current Reading Irrational PMRER_a011_currentReadingIrrational —
Rate Of Change Irrational PMRER_a011_rateOfChangeIrrational —
Sample Freeze PMRER_a011_sampleFreeze —
Vref Irrational PMRER_a011_vrefIrrational —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PMRER_a011.

Browse all PMRER alert codes