Skip to content

PCS_a076 — Dcdc En Deasserted Err

Full alert identifier: PCS_a076_dcdcEnDeassertedErr

Alert description

DCDC PWM enable hardline de-asserted while DCDC was commanded to be active

Potential impact

Inability to precharge HV bus, inability to support 12V system, inability to drive

Set condition

DCDC converter detected that enable line was de-asserted unexpectedly

Clear condition

DCDC converter state machine clears faults

Signals to check

These diagnostic fields are associated with PCS_a076. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Dcdc Enable Line PCS_a076_dcdcEnableLine —
Dcdc Pwm Enable Deasserted Count PCS_a076_dcdcPwmEnableDeassertedCount —
Dcdc Sub State PCS_a076_dcdcSubState —
Pcs Control Request PCS_a076_pcsControlRequest
0
SHUTDOWN
1
SUPPORT
2
PRECHARGE
3
DISCHARGE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a076.

Browse all PCS alert codes