PCS_a054 — Chg Input V Drop Too High
Full alert identifier: PCS_a054_chgInputVDropTooHigh
Message shown in the car
Charging stopped due to large voltage drop Remove extension cords / Have wiring inspected
Alert description
Charging faulted due to too large of a voltage drop between starting charge and during charge
Potential impact
Inability to AC charge, possibly due to bad wiring external to vehicle
Set condition
Charger detects greater than 14% input voltage drop after ramping power
Clear condition
Charge cable is removed or inserted or battery management system issues clear fault request
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Ac Charge Current Limit
PCS_
|
A |
Input Irms
PCS_
|
A |
Input Vrms
PCS_
|
V |
Starting Input Vrms
PCS_
|
V |
| Signal | Unit |
|---|---|
Phase Config
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a054.