PCS_a051 — Chg Int Bus Uv
Full alert identifier: PCS_a051_chgIntBusUv
Alert description
The onboard charger fails to keep the intermediate bus, an internal component involved in AC/DC conversion, at the required voltage. AC charge rate will be reduced, or AC charging may be unavailable.
Potential impact
Reduced AC charge rate or inability to AC charge.
Set condition
The onboard charger intermediate bus voltage is below minimum required voltage threshold.
Clear condition
The onboard charger will restart the affected converter(s) automatically until the maximum number of retry attempts has been reached.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Int Bus Static Ripple
PCS_
|
V |
Int Bus V
PCS_
|
V |
Int Bus V Target
PCS_
|
V |
Llc Current
PCS_
|
A |
Pfc Current Rms
PCS_
|
A |
| Signal | Unit |
|---|---|
Ph State
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a051.