Skip to content

PCS_a036 — Lv Bus Ov

Full alert identifier: PCS_a036_lvBusOv

Alert description

PCS DCDC detects 12V bus voltage is higher than the safety threshold to continue its operation

Potential impact

Inability to precharge HV bus, inability to support 12V system, inability to drive

Set condition

DCDC converter detects that low voltage bus voltage exceeds overvoltage threshold

Clear condition

DCDC converter state machine clears faults

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
LV Bus V PCS_a036_LV_busV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a036.

Browse all PCS alert codes