Skip to content

PCS_a026 — Watchdog Alarmed

Full alert identifier: PCS_a026_watchdogAlarmed

Alert description

PCS experienced a watchdog reset

Potential impact

Inability to AC charge, inability to precharge HV bus, inability to support 12V system, inability to drive

Set condition

Power conversion system was reset by watchdog

Clear condition

Power conversion system reboots

Signals to check

These diagnostic fields are associated with PCS_a026. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
CPU 1 Watchdog Alarmed PCS_a026_CPU1_watchdog_alarmed —
CPU 2 Watchdog Alarmed PCS_a026_CPU2_watchdog_alarmed —
NMI Flag Registers PCS_a026_NMIFlagRegisters —
System Reset Registers PCS_a026_systemResetRegisters —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a026.

Browse all PCS alert codes