PCS_a003 — Chg Hw Input Ov

Full alert identifier: PCS_a003_chgHwInputOv

Alert description

Charger input line over voltage

Potential impact

Reduced AC charge rate or inability to AC charge, possibly due to incompatible grid

Set condition

Charger AC input voltage peak level exceeds maximum input voltage peak threshold

Clear condition

Charger phase state machine clears faults for phase

Signals to check

These diagnostic fields are associated with PCS_a003. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Ph State PCS_a003_phState
0
INIT
1
IDLE
2
PRECHARGE
3
ENABLE
4
FAULT
5
CLEAR FAULTS
6
SHUTTING DOWN
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a003.