Skip to content

IBST_a062 — MICB6 Transfer Error

Full alert identifier: IBST_a062_MICB6TransferError

Message shown in the car

Power braking assist reduced Braking may require increased effort

Alert description

iBooster (IBST) detected Serial Peripheral Interface (SPI) transfer to TLE9180 bridge driver Application-Specific Integrated Circuit (ASIC) has failed (error frame wrong address or timeout CSIH error).

Potential impact

IBST may not operate as expected.

Set condition

IBST detected SPI transfer to TLE9180 bridge driver ASIC has failed.

Clear condition

iBooster can not recover from this condition. iBooster replacement may be required.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of IBST_a062.

Browse all IBST alert codes