HVP_w021 — Pyro Mia Fault
Full alert identifier: HVP_w021_PyroMiaFault
Message shown in the car
Vehicle may not restart Service is required
Alert description
The vehicle detects a condition affecting one or more of the pyrotechnic (pyro) fuses.
Potential impact
The High Voltage (HV) contactors are not allowed to close.
Set condition
The diagnostic test on one or more of the pyro fuses is unsuccessful. This can indicate the pyro fuse has blown.
Clear condition
The pyro fuse diagnostic test passes.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Aout
HVP_
|
V |
Squib Resistance
HVP_
|
Ohm |
| Signal | Unit |
|---|---|
Er Test Failed
HVP_
|
— |
High Side
HVP_
|
— |
High Side Switch Test Failed
HVP_
|
— |
Low Side
HVP_
|
— |
Low Side Switch Test Failed
HVP_
|
— |
One Shot Sequence
HVP_
|
— |
Pyro Leak Test Failed
HVP_
|
— |
Ref Current Test Failed
HVP_
|
— |
Show 3 more fields
| Signal | Unit |
|---|---|
Squib Res Test Failed
HVP_
|
— |
Vst Test Failed
HVP_
|
— |
Pyro Status
HVP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w021.