Skip to content

HVP_w013 — Bmb Communication

Full alert identifier: HVP_w013_BmbCommunication

Alert description

A communication interruption has been detected in the Battery Monitoring Board (BMB) chain

Potential impact

May indicate a loss of BMB sensor data

Set condition

A communication issue with the BMB daisy chain is detected

Clear condition

No communication issues with the BMB daisy chain have been detected

Signals to check

These diagnostic fields are associated with HVP_w013. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bmb Chain Break Type HVP_a013_bmbChainBreakType
0
NONE
1
SINGLE BREAK
2
DOUBLE BREAK
3
INVALID BREAK
4
HEAD BREAK
5
TAIL BREAK
—
Bmb Comm Status Type A HVP_a013_bmbCommStatusTypeA
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Bmb Comm Status Type B HVP_a013_bmbCommStatusTypeB
0
MISSING
1
BAD
2
NOMINAL
3
BYPASSED
—
Break Location A HVP_a013_breakLocationA —
Break Location B HVP_a013_breakLocationB —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w013.

Browse all HVP alert codes