Skip to content

FC_a296 — GB invalid Pilot Transitio

Full alert identifier: FC_a296_GB_invalidPilotTransitio

Alert description

The Fast Charge (FC) Electronic Control Unit (ECU) has received a message from the GuoBiao (GB) adapter detecting the state transition of pilot signal is different from normal transition sequence.

Potential impact

Charging session may not start.

Set condition

The state transition of the pilot signal is irrational.

Clear condition

The pilot signal state transition meets rational expectations.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of FC_a296.

Browse all FC alert codes