Skip to content

EPBR_a241 — Di Output Locked

Full alert identifier: EPBR_a241_diOutputLocked

Alert description

A request to change the DI power state has been denied.

Potential impact

Drive inverter may be faulted

Set condition

Electronic Parking Brake Left detects drive inverter lockout request timed out after 0.5 seconds

Clear condition

Electronic Parking Brake Left unlocks drive inverter output

Signals to check

These diagnostic fields are associated with EPBR_a241. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Current State EPBR_a241_currentState —
Desired State EPBR_a241_desiredState —
Di Keep Alive EPBR_a241_diKeepAlive —
Epb Sys Status EPBR_a241_epbSysStatus —
Has Lockout Request EPBR_a241_hasLockoutRequest —
High Current EPBR_a241_highCurrent —
Monitor Data Good EPBR_a241_monitorDataGood —
Vehicle Power State EPBR_a241_vehiclePowerState
0
OFF
1
CONDITIONING
2
ACCESSORY
3
DRIVE
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPBR_a241.

Browse all EPBR alert codes