Skip to content

EPBL_a170 — 12v Ov

Full alert identifier: EPBL_a170_12vOv

Alert description

The battery voltage measurement, nominally 12 volts, was higher than expected.

Potential impact

12V Battery or low voltage systems may be damaged

Set condition

The vbat voltage measurement is higher than 18.5 volts.

Clear condition

Caliper state machine exits csmState CSM_FAULT

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
12 V Filt EPBL_a170_12vFilt V
Nv Filt EPBL_a170_nvFilt V
Pv Filt EPBL_a170_pvFilt V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPBL_a170.

Browse all EPBL alert codes