Skip to content

EPBL_a123 — Uc

Full alert identifier: EPBL_a123_Uc

Alert description

Motor current was lower than expected

Potential impact

Caliper could be disconnected or the harness is damaged.

Set condition

Motor current measurement, with calibration offset subtracted, was lower than 0.25 amps

Clear condition

Caliper state machine exits csmState CSM_FAULT

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Filtered Current Cal EPBL_a123_filteredCurrentCal A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EPBL_a123.

Browse all EPBL alert codes