Skip to content

DI_a098 — Eeprom Manager Error

Full alert identifier: DI_a098_eepromManagerError

Alert description

The drive interface (DI) electronic control unit (ECU) detects an electrically erasable programmable read-only memory (EEPROM) error. Check for other alerts that may be set as a result.

Potential impact

The DI is not able to store any record in EEPROM where the error is located, which impacts functionality on the next boot up.

Set condition

There are EEPROM record issues, such as corruption, an invalid cyclic redundancy check (CRC), or an invalid record size.

Clear condition

Clears on DI power cycle.

Signals to check

These diagnostic fields are associated with DI_a098. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Error Code DI_a098_errorCode —
Page 0 Counter DI_a098_page0Counter —
Page 1 Counter DI_a098_page1Counter —
Page 2 Counter DI_a098_page2Counter —
Page ID DI_a098_pageID —
Record ID DI_a098_recordID —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DI_a098.

Browse all DI alert codes