Skip to content

DI_a042 — Pmf MIA

Full alert identifier: DI_a042_pmfMIA

Alert description

The drive interface (DI) electronic control unit (ECU) detects that the front propulsion monitor (PMF) controller area network (CAN) node is missing (MIA).

Potential impact

The PM system is unable to determine the PMF state.

Set condition

The DI ECU is not receiving the expected CAN communication from the PMF, and considers the PMF irrational or MIA.

Clear condition

The DI ECU receives the required CAN messages from the PMF.

Signals to check

These diagnostic fields are associated with DI_a042. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
State 4 DI_a042_state4 —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DI_a042.

Browse all DI alert codes