DI_a020 — System Hvil Not Closed
Full alert identifier: DI_a020_systemHvilNotClosed
Alert description
The drive interface (DI) electronic control unit (ECU) detects that the high voltage interlock loop (HVIL) is not closed.
Potential impact
Contactors may not close.
Set condition
Any DI unit reports the HVIL status as missing or not closed.
Clear condition
All DI units report that the HVIL status is closed.
Signals to check
These diagnostic fields are associated with DI_a020. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dif Hvil Status
DI_
|
— |
Dif Status Valid
DI_
|
— |
Dir Hvil Status
DI_
|
— |
Dir Status Valid
DI_
|
— |
Direl Hvil Status
DI_
|
— |
Direl Status Valid
DI_
|
— |
Direr Hvil Status
DI_
|
— |
Direr Status Valid
DI_
|
— |
Show 2 more fields
| Signal | Unit |
|---|---|
Hvil System Status
DI_
|
— |
Vehicle Power State
DI_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DI_a020.